• Gigabit Ethernet-Faser Optik-Transceiver 1,25 SFP-Modul LC SX 1 Paar-Los 20km T1550 R1310nm
  • Gigabit Ethernet-Faser Optik-Transceiver 1,25 SFP-Modul LC SX 1 Paar-Los 20km T1550 R1310nm
  • Gigabit Ethernet-Faser Optik-Transceiver 1,25 SFP-Modul LC SX 1 Paar-Los 20km T1550 R1310nm
  • Gigabit Ethernet-Faser Optik-Transceiver 1,25 SFP-Modul LC SX 1 Paar-Los 20km T1550 R1310nm
Gigabit Ethernet-Faser Optik-Transceiver 1,25 SFP-Modul LC SX 1 Paar-Los 20km T1550 R1310nm

Gigabit Ethernet-Faser Optik-Transceiver 1,25 SFP-Modul LC SX 1 Paar-Los 20km T1550 R1310nm

Produktdetails:

Herkunftsort: SHENZHEN
Markenname: KEXINT
Zertifizierung: ISO900-2008
Modellnummer: KXT-SFP-LCBI-10KM

Zahlung und Versand AGB:

Min Bestellmenge: Verhandlung
Preis: Negotiation
Verpackung Informationen: 20cm x 15cm x 10cm (7.87in x 5.91in x 3.94in)
Lieferzeit: Tag mit 15 Arbeiten
Zahlungsbedingungen: T/T, D/A, L/C, D/P, Western Union, MoneyGram
Versorgungsmaterial-Fähigkeit: 1000 + Paare + 7-tägig
Bestpreis Kontakt

Detailinformationen

Produkt-Name: Optischer Transceiver LC sfp Art: 1 Kern
Anwendung: Netz FTTH FTTX FTTB Datenrate: 1.25G
Wellenlänge: 1310nm/1550nm Verbindungsstück: LC
Abstand: 20KM Garantie: 3-jährig
Markieren:

elektrisches sfp-Modul

,

Faseroptik-Ethernet-Transceiver

Produkt-Beschreibung

Gigabit Ethernet-Faser Optik-Transceiver 1,25 SFP-Modul LC SX 1 Paar-Los 20km T1550 R1310nm
 
PRODUKT-BESCHREIBUNG:

Besteht kleiner Form-Faktor Kexint BIDI-1.25G-1310/1550nm-10km-LC-DDM, den steckbare (SFP-) Transceivers mit der kleinen Form-Faktor-steckbaren Inanspruchnahme- mehrerer quellenvereinbarung (MSA), der Transceiver kompatibel sind, aus fünf Abschnitten: der LD-Fahrer, der Begrenzungsverstärker, der digitale Diagnosemonitor, der 1310nm FP Laser (der 1550nm DFB Laser) und der PIN-Fotodetektor. Die Moduldatenverbindung bis 20KM in der Einmodenfaser 9/125um.

Der optische Ertrag kann durch einen hochrangigen Input TTL-Logiks von Tx-Sperrung behindert sein, und das System kann das Modul über I2C auch sperren. Tx-Störung wird zur Verfügung gestellt, um diese Verminderung des Lasers anzuzeigen. Verlust des Ertrages des Signals (LOS) wird zur Verfügung gestellt, um den Verlust eines optischen Signals des Input des Empfängers oder den Verbindungsstatus mit Partner anzuzeigen. Das System kann die Informationen LOS (oder Verbindung) /Disable/Fault über I2C-Registerzugang auch erhalten.
 
Spezifikation des Übermittlers:
Parameter Symbol Min. Art. Maximum. Einheit Anmerkung
Durchschnittliche Spitzenleistung SCHELLFISCH -9   -3 dBm Anmerkung (1)
Löschungs-Verhältnis ER 9     DB  
Mittelwellenlänge λC 1290 1310 1330 Nanometer XYT-SFP-BX-U
1530 1550 1570 XYT-SFP-BX-D
Spektrum-Breite (Effektivwert) σ     3,5 Nanometer FP Laser
(TX: 1310nm)
Seitenmodus-Unterdrückungs-Verhältnis SMSR 30     DB DFB Laser
Spektrum-Bandbreite (- 20dB) σ     1 Nanometer (TX: 1550nm)
Übermittler WEG von der Spitzenleistung POff     -45 dBm  
Differenziale Linie Eingangsimpedanz RIN 90 100 110 Ohm  
Ertrag-Augen-Maske Konform mit IEEE802.3 z (Lasersicherheit der Klasse 1)   Anmerkung (2)

 

Spezifikation des Empfängers:

Parameter Symbol Min. Art. Maximum. Einheit Anmerkung
Eingegebene optische Wellenlänge λIN 1530 1550 1570 Nanometer XYT-SFP-BX-U
1290 1310 1330 XYT-SFP-BX-D
Empfänger-Empfindlichkeit PIN     -20 dBm Anmerkung (1)
Eingegebene Sättigungs-Energie (Überlastung) PSAT -3     dBm  
Los des Signals erklären PA -35     dBm  
Los des Signals De-erklären PD     -22 dBm Anmerkung (2)
Los-Hysterese PA-PD 0,5 2 6 DB  

 

Produkt-Eigenschaften:

1) Optische Schnittstelle einzelnen LC- oder Sc-Behälters konform

2) Heiß-steckbarer SFP-Abdruck

3) 1310nm FP Laser-Übermittler; 1550nm DFB Laser-Übermittler

4) RoHS konform und bleifrei

5) Bis 3km auf 9/125um SMF

6) Metalleinschließung für niedrigere EMS

7) Einzelne Stromversorgung 3.3V

8) Ableitung der geringen Energie <600mw>

9) Handelsbetriebstemperaturbereich: 0 bis 70

10) Digital-Diagnoseüberwachung optional

 

Anwendungen:
Gigabit Ethernet
Faser-Kanal
Verdrahtungshandbuch-Anwendung

 

General:

Kleine steckbare (SFP) Transceivers des Form-Faktors sind mit der kleinen Form-Faktor-steckbaren Inanspruchnahme- mehrerer quellenvereinbarung (MSA) kompatibel. Sie willigen gleichzeitig mit Gigabit Ethernet ein, wie IN IEEE-Geschlechtskrankheit 802,3 und dem Kanal in der Faser-spezifiziert 1x, wie in FC-PI-2 Rev. 10,0 definiert. Sie sind konformes und bleifreies RoHS.

 

kEXINT SFP-FORM:

Name Modell Verkapselung Frequenz Wellenlänge Abstand Medien Verbindungsstück DDM Temperatur
QSFP28 100G KXTQP28-100G-SR4 QSFP28 103G 850nm 100m MMF MPO JA 0℃~70℃
KXTQP28-100G-LR4 QSFP28 103G 1295.56/1300.05/
1304.58/1309.14nm
10km SMF LC JA 0℃~70℃
KXTQP28-100G-CLR4
CWDM4
QSFP28 103G 1271/1291/
1311/1331nm
2km SMF LC JA 0℃~70℃
KXTQP28-100G-PSM4 QSFP28 103G 1310nm 500m SMF MPO JA 0℃~70℃
KXTQP28-100G-LR4-A QSFP28 103/112G 1295.56/1300.05/
1304.58/1309.14nm
10km DML SMF LC JA 0℃~70℃
KXTQP28-100G-LR4-B QSFP28 103/112G 1295.56/1300.05/
1304.58/1309.14nm
10km EML SMF LC JA 0℃~70℃
CFP4 100G KXTCP4-100G-SR10 CFP4 103G 850nm 100m MMF MPO JA 0℃~70℃
KXTCP4-100G-LR4 CFP4 103G 1295.56/1300.05/
1304.58/1309.14nm
10km SMF LC JA 0℃~70℃
CFP2 100G KXTCP2-100G-SR10 CFP2 103G 850nm 100m MMF MPO JA 0℃~70℃
KXTCP2-100G-LR4 CFP2 103G 1295.56/1300.05/
1304.58/1309.14nm
10km SMF LC JA 0℃~70℃
KXTCP2-100G-ER4 CFP2 103G 1295.56/1300.05/
1304.58/1309.14nm
40km SMF LC JA 0℃~70℃
CFP 100G KXTCP-100G-SR10 CFP 103G 850nm 100m MMF MPO JA 0℃~70℃
KXTCP-100G-LR4 CFP 103G 1295.56/1300.05/
1304.58/1309.14nm
10km SMF LC JA 0℃~70℃
KXTCP-100G-ER4 CFP 103G 1295.56/1300.05/
1304.58/1309.14nm
40km SMF LC JA 0℃~70℃
QSFP+ 40G KXTQP-40G-SR4 QSFP+ 40G 850nm 100m MMF MPO JA 0℃~70℃
KXTQP-40G-SR-BD QSFP+ 40G 850/900nm 100m MMF LC JA 0℃~70℃
KXTQP-40G-LR4 QSFP+ 40G 1295.56/1300.05/
1304.58/1309.14nm
10km SMF LC JA 0℃~70℃
KXTQP-40G-ER4 QSFP+ 40G 1295.56/1300.05/
1304.58/1309.14nm
30km SMF LC JA 0℃~70℃
KXTQP-40G-ER4 QSFP+ 40G 1295.56/1300.05/
1304.58/1309.14nm
40km SMF LC JA 0℃~70℃
QSFP 25G KXTQP-25G-SR4 SFP28 25G 850nm 100m MMF LC JA 0℃~70℃
KXTQP-25G-LR4 SFP28 25G 1295.56/1300.05/
1304.58/1309.14nm
10km SMF LC JA 0℃~70℃
KXTQP-25G-LR4 SFP28 25G 1295.56/1300.05/
1304.58/1309.14nm
10km SMF LC JA „- 40℃~85℃
10G SFP+ MILLIMETER KXTPP-10G-SR SFP+ 10G 850nm 300m MMF LC JA 0℃~70℃
KXTPP-10G-LRM SFP+ 10G 1310nm 220m MMF LC JA 0℃~70℃
10G SFP+ INSPEKTION KXTPP-10G-LR SFP+ 10G 1310nm 10km SMF LC JA 0℃~70℃
KXTPP-10G-ER-13 SFP+ 10G 1310nm 40km SMF LC JA 0℃~70℃
KXTPP-10G-ER SFP+ 10G 1550nm 40km SMF LC JA 0℃~70℃
KXTPP-10G-ZR SFP+ 10G 1550nm 80km SMF LC JA 0℃~70℃
10G SFP+ CWDM KXTPP-10G-C ** - 40 SFP+ 10G 1270~1450nm 40km SMF LC JA 0℃~70℃
KXTPP-10G-C ** - 40 SFP+ 10G 1470~1610nm 40km SMF LC JA 0℃~70℃
KXTPP-10G-C ** - 80 SFP+ 10G 1470~1610nm 80km SMF LC JA 0℃~70℃
10G SFP+ DWDM KXTPP-10G-D ** - 40 SFP+ 10G C20~C59 40km SMF LC JA 0℃~70℃
KXTPP-10G-D ** - 80 SFP+ 10G C20~C59 80km SMF LC JA 0℃~70℃
10G SFP+ BiDi KXTPP-10G-B10-23 SFP+ 10G T1270/R1330nm 10km SMF LC JA 0℃~70℃
KXTPP-10G-B10-32 SFP+ 10G T1330/R1270nm 10km SMF LC JA 0℃~70℃
KXTPP-10G-B40-23 SFP+ 10G T1270/R1330nm 40km SMF LC JA 0℃~70℃
KXTPP-10G-B40-32 SFP+ 10G T1330/R1270nm 40km SMF LC JA 0℃~70℃
KXTPP-10G-B60-23 SFP+ 10G T1270/R1330nm 60km SMF LC JA 0℃~70℃
KXTPP-10G-B60-32 SFP+ 10G T1330/R1270nm 60km SMF LC JA 0℃~70℃
KXTPP-10G-B80-45 SFP+ 10G T1490/R1550nm 80km SMF LC JA 0℃~70℃
KXTPP-10G-B80-54 SFP+ 10G T1550/R1490nm 80km SMF LC JA 0℃~70℃
10G XFP MILLIMETER KXTXP-10G-SR XFP 10G 850nm 300m MMF LC JA 0℃~70℃
KXTXP-10G-LRM XFP 10G 1310nm 220m MMF LC JA 0℃~70℃
10G XFP INSPEKTION KXTXP-10G-LR XFP 10G 1310nm 10km SMF LC JA 0℃~70℃
KXTXP-10G-ER-13 XFP 10G 1310nm 40km SMF LC JA 0℃~70℃
KXTXP-10G-ER XFP 10G 1550nm 40km SMF LC JA 0℃~70℃
KXTXP-10G-ZR XFP 10G 1550nm 80km SMF LC JA 0℃~70℃
10G XFP CWDM KXTXP-10G-C ** - 40 XFP 10G 1270~1450nm 40km SMF LC JA 0℃~70℃
KXTXP-10G-C ** - 40 XFP 10G 1470~1610nm 40km SMF LC JA 0℃~70℃
KXTXP-10G-C ** - 80 XFP 10G 1470~1610nm 80km SMF LC JA 0℃~70℃
10G XFP DWDM KXTXP-10G-D ** - 40 XFP 10G C20~C59 40km SMF LC JA 0℃~70℃
KXTXP-10G-D ** - 80 XFP 10G C20~C59 80km SMF LC JA 0℃~70℃
KXTXP-10G-DT-80 XFP 10G Melodisch 80km SMF LC JA 0℃~70℃
X2 ZU SFP+ X2 zu SFP+-Konverter - 10G         Nein 0℃~70℃
                   
1.25G
Elektrischer Hafen
KXTFP-GE-T SFP 1000M   100m UTP RJ45 NEIN 0℃~70℃
KXTFP-GE-TA SFP 10/100/1000M   100m UTP RJ45 NEIN 0℃~70℃
1.25G MILLIMETER KXTFP-GE-SX SFP 1.25G 850nm 550m MMF LC JA 0℃~70℃
1.25G SFP INSPEKTION KXTFP-GE-LX SFP 1.25G 1310nm 20km SMF LC JA 0℃~70℃
KXTFP-GE-EX SFP 1.25G 1310nm 40km SMF LC JA 0℃~70℃
KXTFP-GE-EX-15 SFP 1.25G 1550nm 40km SMF LC JA 0℃~70℃
KXTFP-GE-ZX SFP 1.25G 1550nm 80km SMF LC JA 0℃~70℃
KXTFP-GE-EZX SFP 1.25G 1550nm 120km SMF LC JA 0℃~70℃
KXTFP-GE-150 SFP 1.25G 1550nm 150km SMF LC JA 0℃~70℃
1.25G SFP CWDM KXTFP-GE-C ** - 40 SFP 1.25G 1270~1610nm 40km SMF LC JA 0℃~70℃
KXTFP-GE-C ** - 80 SFP 1.25G 1270~1610nm 80km SMF LC JA 0℃~70℃
KXTFP-GE-C ** - 100 SFP 1.25G 1270~1610nm 100km SMF LC JA 0℃~70℃
KXTFP-GE-C ** - 120 SFP 1.25G 1270~1610nm 120km SMF LC JA 0℃~70℃
KXTFP-GE-C ** - 150 SFP 1.25G 1270~1610nm 150km SMF LC JA 0℃~70℃
1.25G SFP DWDM KXTFP-GE-D ** - 40 SFP 1.25G C20~C59 40km SMF LC JA 0℃~70℃
KXTFP-GE-D ** - 80 SFP 1.25G C20~C59 80km SMF LC JA 0℃~70℃
KXTFP-GE-D ** - 100 SFP 1.25G C20~C59 100km SMF LC JA 0℃~70℃
KXTFP-GE-D ** - 120 SFP 1.25G C20~C59 120km SMF LC JA 0℃~70℃
1.25G SFP BiDi KXTFP-GE-B20-35 SFP 1.25G T1310/R1550nm 20km SMF LC JA 0℃~70℃
KXTFP-GE-B20-53 SFP 1.25G T1550/R1310nm 20km SMF LC JA 0℃~70℃

 

Gigabit Ethernet-Faser Optik-Transceiver 1,25 SFP-Modul LC SX 1 Paar-Los 20km T1550 R1310nm 0 

Möchten Sie mehr über dieses Produkt erfahren?
Ich bin daran interessiert Gigabit Ethernet-Faser Optik-Transceiver 1,25 SFP-Modul LC SX 1 Paar-Los 20km T1550 R1310nm Könnten Sie mir weitere Details wie Typ, Größe, Menge, Material usw. senden?
Vielen Dank!
Auf deine Antwort wartend.